IBEX ULTRA

IBEX is the battery diagnostic tester that can measure an internal resistance of a battery, and which is compatible IEEE Std. 1188-1996 and 2005 “Recommended Practice for Maintenance, Testing, and Replacement for Stationary Applications.”

Description

IBEX-ultra (Intelligent Battery Examiner)

The IBEX-ULTRA includes:

  • IBEX-ULTRA Body with printable means
  • Li-Ion Battery inside Body
  • Soft Poly-Vinyl Bag with ZERO Adjustable Plate
  • Standard Charger (100 to 240 VAC)
  • 4-Pin type Probe
  • Clip Type Probe
  • Temperature Probe
  • English Users Manual
  • Bundled Software: Serial Comm
  • USB Cable to upload PC
  • Diagnosis Software: Exmons Ultra (Multi-User Environment)
  • Plastic Carrying Case (450×340×120)
  • Shunt (50mV/50A, 1mΩ, 1.0 Class)
  • Spare 4-Pin Tip
  • Spare Li-ion Battery
  • IR Thermal Printer
  • Paper Roll for IR Printer
  • 220V AC Standard Charger for IR Printer
  • Spare Paper Roll for IR Printer
  • DC Clamp Meter to measure a ripple current %

IBEX-ULTRA Technical Specifications

Measuring Items • Voltage: 0.1V ~60V. Internal Resistance. Inter-cell Resistance. Terminal Temperature. Automatic Measurement Speed: Within 4 seconds per cell/unit
Output Display: Terminal Temperature. Excel Data 3D graph of value and trend. Capacity: 5Ah ~ max. 6000 Ah. Software: Exmons Ultra Multi-User Battery Management. Accuracy: Cell/Jar Voltage: ±0.5 class. Internal Resistance: ±1.0% rdg. ±8dgt. (in 3 milliohm full-scale) across test range. Temperature: ±2.0 class (-20°C ~ +80°C)
Supporting Functions • Auto-Scanning, Zero-value adjustment. USB interface: Max Storage Data: 4,800. Resolution: DC Voltage: 10mv. Resistance: 0.001 m. Temperature: 0.5°C. User Setting: High/Low Voltage Alarm Setting,  High/Low Resistance Alarm Setting, High/Low Temp. Alarm Setting. User-Friendly Menu display. Protocol: Binary or Standard ASCII Text. Built-in Battery: Li-Ion Battery (2,200Ah, 11.1V). Date Format: Excel 2000/2002, Win 98/2000/XP/Vista compatible. 80 Alarm Setting Files.